- Reactors[6]
- Other Lab Supplies[6]
- Pressure Vessels[4]
- Measuring & Analysing Instrument Processing Services[1]
- Pumps[6]
- Laboratory Thermostatic Devices[6]
- Other Chemical Equipment[6]
- Other Measuring & Analysing Instruments[6]
- Other Optics Instruments[2]
- Testing Equipment[6]
- Refractometers[2]
- Medical Consumables[5]
- Quartz Plate[1]
- Other Analysis Instruments[6]
- Spectrometers[6]
- Mercury Lamps[1]
- PH Meters[6]
- Concentration Meters[1]
- Ice Makers[6]
- Laboratory Bottle[6]
- Ultrasonic Cleaners[6]
- Drying Equipment[5]
- Pipette[6]
- Weighing Scales[6]
- Software[5]
- Integrated Circuits[1]
- Laboratory Centrifuge[6]
- Laboratory Heating Equipments[6]
- Mixing Equipment[5]
- Evaporator[6]
- Material Handling Equipment Parts[5]
- Contact Person : Mr. Du Martin
- Company Name : Zhengzhou Boke Instrument Equipment Co., Ltd.
- Tel : 86-371-67896722
- Fax : 86-371-67896722
- Address : Henan,Zhengzhou,No.A551, 5/F, Buiding 2, No.96 Science and Technology Square, Ruida Road, High Tech Zone
- Country/Region : China
- Zip : 450000
Related Product Searches:10-50ul Pipettor Pipette Micropipettor Micropipette Pipetman Liquid handing,High Quality,pipettor Liquid handing, pipette,TopPette
10-50ul Pipettor Pipette Micropipettor
Micropipette Pipetman Liquid handing
Introduction:
It uses the air displacement principle, the piston in the piston sleeve moving at a fixed range (adjustable), to generate negative pressure, suck in quantitative (adjustable) liquid. It has the advantages for convenient use, reliable performance.
Picture:
Main Specifications:Different measuring range could be chose:
5-25ul10-50ul50-250ul100-500ul200-1000ul
Method of Use:
1. Put the nozzle on the pipetting head, and rotates gently, so as to ensure the sealing is well.2. Before using, please suck in or discharge the liquid of the pipette for several times, in order to ensure inside and outside of the chamber pressure are the same.3. Hold the pipette vertical, set the button to the first stopping point, and put the suction nozzle immersed into the liquid, under the liquid surface 2-3mm, then slowly release the button, waiting for 1-2 seconds, after that, take it out from the liquid, and do not let it touch anything.4. Move the suction nozzle to the sample container wall, slowly push the button to the first stopping point, waiting for 1-2 seconds, then push the button, exhaust all the liquid, the suction nozzle should be slided out along the vessel wall, then slowly release the button, that is a complete operation process.
10-50ul Pipettor Pipette Micropipettor Micropipette Pipetman Liquid handing